Efficiency and safety of thread implantology in the long term: data from a pathomorphological study
https://doi.org/10.33667/2078-5631-2024-9-87-90
Abstract
The evolution of methods used in aesthetic medicine includes a transition to less invasive procedures with high safety and minimal recovery time. That is why numerous non-invasive methods for correcting involutive changes in facial skin (thread lifting, hardware techniques) have been studied for effectiveness and safety over the past decades. Such techniques can improve treatment results and avoid or delay surgical intervention.
Material and methods. The work involved a pathomorphological study of material taken by biopsy at the sites of thread implantation and surrounding tissues (1 cm indentation) (Nano spring, Excellence Visage, Excellence Visage HA) within 12 months after thread lifting. Paraffin sections with a thickness of 5–7 microns were made from ready-made paraffin blocks and stained with: hematoxylin – eosin; according to the Weigert-Van Gieson method; Sirius Red paint. Using a microscope with a Sony digital photo attachment with a resolution of 12 megapixels, five photographs were taken from each histological specimen.
Research results. As a result of a pathomorphological study of a flap of skin and subcutaneous fat with a synthetic thread in the adipose tissue, it was revealed that along the periphery of the studied material there was moderate chronic inflammation (giant cells of the type of foreign body cells, lymphocytes, fibroblasts) and weak fibrosis, as well as a predominance type I collagen in the skin, and type III collagen predominated in subcutaneous fat tissue.
About the Authors
D. N. SerovRussian Federation
Dmitry N. Serov - PhD Med, chief physician.
Khimki
M. S. Kruglova
Russian Federation
Maria S. Kruglova - 3rd year student of the Faculty of Medicine.
Moscow
References
1. Yoo K. H., Kim W. S., Hong K. K., Kim B. J. Chronic inflammatory reaction after thread lifting: a delayed, unusual complication of non-absorbable thread. Dermatol Surg. 2015 April; 41 (4): 510–3.
2. Sarygul Guduk S., Karadzha N. Safety and complications of absorbable poly-L-lactic acid and polylactide/glycolide sutures: an experience in 148 consecutive patients. J Cosmet Dermatol. 2018 Dec; 17 (6): 1189–1193.
3. Wu W. T. Serrated sutures for facial rejuvenation. Aesthete Surg J. 2008; 28 (3): 335–47. 582–7.
4. Rachel J. D., Luck E. B., Larson B. Rates of complications and early recurrence in 29 patients after facial rejuvenation with a barbed suture lift. Dermatol Surg 2010; 36: 348–54.
5. Lee C. J., Park J. G., Yoo S. G., Hwang J. G. et al. Dysesthesia and fasciculation: Unusual complications after face lift with barbed sutures. Dermatol Surg 2007; 33: 253–5.
6. Sulamanidze M., Sulamanidze G., Vozdvizhensky I., Sulamanidze S. Avoiding complications when applying Aptos sutures. «Aesthete Surg J.» 2011; 31: 863–73 (In Russ).
Review
For citations:
Serov D.N., Kruglova M.S. Efficiency and safety of thread implantology in the long term: data from a pathomorphological study. Medical alphabet. 2024;(9):87-90. (In Russ.) https://doi.org/10.33667/2078-5631-2024-9-87-90