Preview

Medical alphabet

Advanced search

The use of modern endomotor in Reciproc mode

Abstract

Providing optimal root canal irrigation and subsequent sealing of the size and shape is a necessary component at the stage of endodontic treatment of teeth. The creation of these optimal conditions is often complicated anatomical features of the structure of root canals, obliteration of, prior poor treatment. Application of modern Nickel-titanium endodontic instruments together with a new improved entomotherapy allows root canal treatment better, faster, without a big risk of complications, while maintaining the anatomical form of the channel.

About the Authors

K. G. Karakov
Stavropol State Medical University
Russian Federation


A. V. Oganyan
Stavropol State Medical University
Russian Federation


T. N. Vlasova
Stavropol State Medical University
Russian Federation


N. A. Mordasov
Stavropol State Medical University
Russian Federation


P. A. Savelyev
Stavropol State Medical University
Russian Federation


M. P. Porfyriadis
Stavropol State Medical University
Russian Federation


A. E. Hachaturyan
Stavropol State Medical University
Russian Federation


References

1. Bishop K, Dummer PM. A comparison of stainless steel Flexofiles and nickel -titanium NiTi Flex files during the shaping of simulated canals. Int Endod J. J997; 30: 25-34

2. Thompson SA, Dummer PMH. Shaping ability of ProFile.04 taper series 29 rotary nickel-titanium instruments in simulated canals: part J. Int Endod J. J997; 30:J-7.

3. Thompson SA, Dummer PMH. Shaping ability of Hero 642 rotary nickel- titanium instruments in simulated root canals: part J. Int Endod J. 2000; 33: 248-54.

4. Garip Y, Gunday M. The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals. Int Endod J. 200J; 34: 452-457.

5. Schafer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile: part J. Shaping ability in sim ulated curved canals. Int Endod J. 2002; 35:505-J3.

6. SchaferE, Florek H. Efficiency of rotary nickel-titanium K3 instruments compared with stainless-steel hand KFlexofile. Part 1. Shaping ability in simulated curved canals. Int Endod J. 2003; 36: 199-207.

7. Караков К. Г., Оганян А. В., Власова Т. Н., Чониашвили Д. З., Соловьева О. А., Саркисов А. А., Мордасов Н. А. Взаимосвязь механических свойств никель-титанового инструмента размера 06/25 в момент заклинивания в прямом корневом канале зуба. / Медицинский алфавит. 2016. Т. 2. № 9 (272). С. 59-60.

8. Соловьева О. А., Караков К. Г., Хачатурян Э. Э., Савельев П. А., Ванченко Н. Б. Эндодонтическое лечение периодонтитов. / В сборнике: Актуальные вопросы клинической стоматологии 2017. С. 145-147.


Review

For citations:


Karakov K.G., Oganyan A.V., Vlasova T.N., Mordasov N.A., Savelyev P.A., Porfyriadis M.P., Hachaturyan A.E. The use of modern endomotor in Reciproc mode. Medical alphabet. 2018;1(2):45-47. (In Russ.)

Views: 274


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2078-5631 (Print)
ISSN 2949-2807 (Online)