Preview

Medical alphabet

Advanced search

Linear immune blotting technology for diagnosis of syphilis

Abstract

A new domestic kit of "Line-Blot Syphilis ” reagents was developed to determine specific antibodies of classes G or M to T. pallidum in linear immune blotting format (IgG in the kit No. I and IgM in the kitNo. 2). The study of control materials of industrial production with a new set revealed 100 percent sensitivity and specificity of research results. A study of 341 clinical specimens obtained from patients with syphilis of patients who underwent examination and those without indication of the presence of syphilis, with the developed kit, made it possible to determine its clinical informativity (clinical sensitivity and specificity): with the kit No. 1 (IgG) 98.8 and 98.3 % and 86.7 and 100 % respectively with the the kit No. 2. The obtained results substantiated the recommendations to its application for the diagnosis of syphilis and the verification of the results of other treponemospecific tests (RIF, ELISA, and RPGA) that do not agree with each other.

About the Authors

V. A. Arsenyeva
ECOlab Co
Russian Federation


E. A. Amelina
ECOlab Co
Russian Federation


S. G. Mardanly
State University of Humanities and Technology; ECOlab Co
Russian Federation


S. V. Rotanov
Russian National Research Medical University n.a. N. I. Pirogov; ECOlab Co
Russian Federation


References

1. UK National Guidelines on the Management of Syphilis, 2008. [http://www.bashh. org/documents/1879].

2. Sokolovskiy E., Frigo N., Rotanov S., Savicheva A., Dolia O. et al. Guidelines for the laboratory diagnosis of syphilis in East-European countries. J. Eur. Academy Dermatol. Venereol. 2009; 23 (6): 623-632.

3. Бондарева В. П., Дерябина В. П., Захарова Е. Н. и др. Современные подходы к лабораторной диагностике сифилиса. Клин. лаборат. диагностика 2010; 11: 46-48.

4. Ткачев В. К. Современный алгоритм серологической диагностики сифилиса: возможности и проблемы. Новости «Вектор-Бест 2012; 3 (65): 2-6. [http://www. vector-best.ru/nvb/n65/st65_1.htm].

5. Фриго Н. В., Ротанов С. В., Манукьян Т. Е., Катунин Г. А., Суворова А. А., и др. Лабораторная диагностика сифилиса: вчера, сегодня, завтра. Вестник дерматол. и венерол. 2012; 4: 16-23.

6. Hagedorn H. J. Kraminer-Hagedorn A., De Bosschere K.et al. Evaluation of INNO-LIA syphilis assay as a confirmatory test for syphilis. J. Clin. Microbiol. 2002; 40 (3): 973-978.

7. Чернова Т. А., Гордеева Г. В., Прокопьева А. Е. Линейный иммуноблот - новый диагностический тест для серодиагностики сифилиса. Клин. дерматол. и венерол. 2005; 1: 21-22.

8. Фриго Н. В., Дударева А. А., Ротанов С. В., Иванов А. М. Иммуноблоттинг в диагностике ранних форм сифилиса. Вестник дерматол. и венерол. 2008; 4: 57-62.

9. Марданлы С. Г., Ротанов С. В., Амелина Е. А. и др. Разработка нового набора реагентов для линейного иммуноблоттинга с целью диагностики сифилиса. II Конгресс Евроазиатской ассоциации дерматовенерол. М., 2012: 120.

10. Brinkman M. B., McKevitt M., McLouglin M.et al. Reactivity of Antibodies from Syphilis Patients to a Protein Array Representing the Treponema pallidum Proteome. J. Clin. Microbiol. 2006 (Mar); 44 (3): 888-891.

11. McGill M.A., Edmondson D. G., Carroll J.A. et al. Characterization and Serologic Analysis of the Treponema pallidum Proteome. Infection and immunity 2010; 78 (6): 2631-2643.

12. Ротанов С. В., Хайруллин Р. Ф., Фриго Н. В. Изучение протеома T. pallidum с целью совершенствования лабораторных исследований для диагностики сифилиса. Вестник дерматол. и венерол. 2012; 4: 10-15.

13. Хайруллин Р. Ф., Ротанов С. В., Фриго Н. В., Белоусова А. В. Биоинформатический анализ специфических антигенов T. pallidum. Вестник дерматол. и венерол. 2012; 5: 56-64.

14. Марданлы С. Г., Арсеньева В. А. Новая тест-система «Аайн-Блот Сифилис - IgM» для определения IgM-антител к Treponema pallidum методом линейного иммуноблоттинга. Вестник службы крови 2014; 1: 44-47.

15. Национальный стандарт Российской Федерации. ГОСТ Р 53022.3-2008. «Технологии лабораторные клинические. Требования к качеству клинических лабораторных исследований. Часть 3. Правила оценки клинической информативности лабораторных тестов».


Review

For citations:


Arsenyeva V.A., Amelina E.A., Mardanly S.G., Rotanov S.V. Linear immune blotting technology for diagnosis of syphilis. Medical alphabet. 2017;2(18):34-37. (In Russ.)

Views: 613


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2078-5631 (Print)