<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medalphabet</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинский алфавит</journal-title><trans-title-group xml:lang="en"><trans-title>Medical alphabet</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2078-5631</issn><issn pub-type="epub">2949-2807</issn><publisher><publisher-name>ООО «Альфмед»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">medalphabet-752</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Исследование технических и эксплуатационных характеристик наиболее распространенных ЭЭГ шлемов с общим разъемом</article-title><trans-title-group xml:lang="en"><trans-title>E-valuation of technical and operational characteristics of well-known EEG caps with common connector</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Забодаев</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Zabodaev</surname><given-names>S. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ООО «Медицинские компьютерные системы»;  Национальный исследовательский университет «МИЭТ»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>National Research University of Electronic Technology - MIET</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>27</day><month>07</month><year>2018</year></pub-date><volume>2</volume><issue>23</issue><issue-title>Современная функциональная диагностика</issue-title><fpage>41</fpage><lpage>44</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Забодаев С.В., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Забодаев С.В.</copyright-holder><copyright-holder xml:lang="en">Zabodaev S.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.med-alphabet.com/jour/article/view/752">https://www.med-alphabet.com/jour/article/view/752</self-uri><abstract><p>В статье представлены результаты анализа технических, эксплуатационных и потребительских свойств наиболее распространенных на территории Российской Федерации и Европы шлемов с общим разъемом для регистрации клинической ЭЭГ: Electro-cap, MCScap и WaveGuard connect.</p></abstract><trans-abstract xml:lang="en"><p>The article presents results of evaluation of technical, operational and consumer properties of the well-known caps with common connector for recording of clinical EEG on the territory of the Russian Federation and Europe: Electro-cap, MCScap and WaveGuard connect.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>ЭЭГ</kwd><kwd>неврология</kwd><kwd>электрод</kwd><kwd>поляризация</kwd></kwd-group><kwd-group xml:lang="en"><kwd>EEG</kwd><kwd>neuroscience</kwd><kwd>electrode</kwd><kwd>polarization</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Nuwer MR, Comi G, Emerson R, Fuglsang-Frederiksen A, Guérit JM, Hinrichs H, Ikeda A, Luccas FJ, Rappelsberger P. IFCN standards for digital recording of clinical EEG International Federation of Clinical Neurophysiology // Electroencephalogr Clin Neurophysiol Suppl. 1999. V. 52:11-4. P. 259-261.</mixed-citation><mixed-citation xml:lang="en">Nuwer MR, Comi G, Emerson R, Fuglsang-Frederiksen A, Guérit JM, Hinrichs H, Ikeda A, Luccas FJ, Rappelsberger P. IFCN standards for digital recording of clinical EEG International Federation of Clinical Neurophysiology // Electroencephalogr Clin Neurophysiol Suppl. 1999. V. 52:11-4. P. 259-261.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C. et al. The standardized EEG electrode array of the IFCN // Clin Neurophysiol. 2017. V. 128. P. 2070-2077.</mixed-citation><mixed-citation xml:lang="en">Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C. et al. The standardized EEG electrode array of the IFCN // Clin Neurophysiol. 2017. V. 128. P. 2070-2077.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 25995-83. Электроды для съема биоэлектрических потенциалов. Общие технические требования и методы испытаний [Текст]. - Москва: Изд-во стандартов, 1984. - 25 с.</mixed-citation><mixed-citation xml:lang="en">ГОСТ 25995-83. Электроды для съема биоэлектрических потенциалов. Общие технические требования и методы испытаний [Текст]. - Москва: Изд-во стандартов, 1984. - 25 с.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Tallgren P, Vanhatalo S, Kaila K, Voipio J. Evaluation of commercially available electrodes and gels for recording of slow EEG potentials // Clinical Neurophysiology. 2005. V. 116. P. 799-806.</mixed-citation><mixed-citation xml:lang="en">Tallgren P, Vanhatalo S, Kaila K, Voipio J. Evaluation of commercially available electrodes and gels for recording of slow EEG potentials // Clinical Neurophysiology. 2005. V. 116. P. 799-806.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Huigen, E., Peper, E., Grimbergen, C. A. Investigation into the origin of the noise of surface electrodes // Med Biol Eng Comput. 2002. V. 40. P. 332-338.</mixed-citation><mixed-citation xml:lang="en">Huigen, E., Peper, E., Grimbergen, C. A. Investigation into the origin of the noise of surface electrodes // Med Biol Eng Comput. 2002. V. 40. P. 332-338.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Voipio, J., Tallgren, P., Heinonen, E., Vanhatalo, S., Kaila, K. Ultraslow DC shifts in the human EEG: evidence for a non-neuronal generator // J Neurophysiol. 2003. V. 89. P. 2208-2214.</mixed-citation><mixed-citation xml:lang="en">Voipio, J., Tallgren, P., Heinonen, E., Vanhatalo, S., Kaila, K. Ultraslow DC shifts in the human EEG: evidence for a non-neuronal generator // J Neurophysiol. 2003. V. 89. P. 2208-2214.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">H. H. Jasper. The ten-twenty electrode system of the International Federation // Electroencephalogr Clin Neurophysiol. 1958. V. 10. P. 371-375.</mixed-citation><mixed-citation xml:lang="en">H. H. Jasper. The ten-twenty electrode system of the International Federation // Electroencephalogr Clin Neurophysiol. 1958. V. 10. P. 371-375.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Rosenzweig I, Fogarasi A, Johnsen B, Alving J, Fabricius ME, Scherg M, et al. Beyond the double banana: improved recognition of temporal lobe seizures in longterm EEG // J Clin Neurophysiol. 2014 V. 31. P. 1-9.</mixed-citation><mixed-citation xml:lang="en">Rosenzweig I, Fogarasi A, Johnsen B, Alving J, Fabricius ME, Scherg M, et al. Beyond the double banana: improved recognition of temporal lobe seizures in longterm EEG // J Clin Neurophysiol. 2014 V. 31. P. 1-9.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Koessler L, Cecchin T, Colnat-Coulbois S, Vignal JP, Jonas J, Vespignani H, et al. Catching the invisible: mesial temporal source contribution to simultaneous EEG and SEEG recordings // Brain Topogr. 2015. V. 28(1). P. 5-20.</mixed-citation><mixed-citation xml:lang="en">Koessler L, Cecchin T, Colnat-Coulbois S, Vignal JP, Jonas J, Vespignani H, et al. Catching the invisible: mesial temporal source contribution to simultaneous EEG and SEEG recordings // Brain Topogr. 2015. V. 28(1). P. 5-20.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Vanhatalo, S., Voipio, J. &amp; Kaila, K. Fullband EEG (fbEEG): a new standard for clinical electroencephalography // Clin. EEG Neurosci. 2005. V. 36. P. 311-317.</mixed-citation><mixed-citation xml:lang="en">Vanhatalo, S., Voipio, J. &amp; Kaila, K. Fullband EEG (fbEEG): a new standard for clinical electroencephalography // Clin. EEG Neurosci. 2005. V. 36. P. 311-317.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
