<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medalphabet</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинский алфавит</journal-title><trans-title-group xml:lang="en"><trans-title>Medical alphabet</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2078-5631</issn><issn pub-type="epub">2949-2807</issn><publisher><publisher-name>ООО «Альфмед»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.33667/2078-5631-2024-35-90-94</article-id><article-id custom-type="elpub" pub-id-type="custom">medalphabet-4138</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Снижение микробного фона в отделении реанимации и интенсивной терапии хирургического стационара при системном внедрении в дезинфекционные мероприятия импульсной ультрафиолетовой системы «Альфа‑06А» (экспериментальное исследование)</article-title><trans-title-group xml:lang="en"><trans-title>Reduction of the microbial background in the intensive care unit of a surgical hospital with the systematic introduction of the Alpha‑06A pulsed ultraviolet system into disinfection measures (experimental study)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2537-954X</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Струнин</surname><given-names>О. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Strunin</surname><given-names>O. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Струнин Олег Всеволодович, д. м. н. заведующий отделением анестезиологии-реанимации с палатами реанимации и интенсивной терапии</p><p>Москва</p></bio><bio xml:lang="en"><p>Strunin Oleg V., DM Sci (habil.), head of Anesthesiology and Resuscitation Dept with Resuscitation and Intensive Care Units</p><p>Moscow</p></bio><email xlink:type="simple">strunin@ixv.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Терехова</surname><given-names>Р. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Terekhova</surname><given-names>R. P.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Терехова Раиса Петровна, к. м. н. заведующая лабораторией профилактики и лечения бактериальных инфекций</p><p>Москва</p></bio><bio xml:lang="en"><p>Terekhova Raisa P., PhD Med, head of Laboratory for Prevention and Treatment of Bacterial Infections</p><p>Moscow</p></bio><email xlink:type="simple">Terechova@ixv.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-1245-3694</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Козлова</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Kozlova</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Козлова Алевтина Владимировна, д. м. н., заместитель главного врача по санитарно-эпидемиологической работе</p><p>Москва</p></bio><bio xml:lang="en"><p>Kozlova Alevtina V., DM Sci (habil.), deputy chief physician for Sanitary and Epidemiological Work</p><p>Moscow</p></bio><email xlink:type="simple">KozlovaAV@ixv.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-3187-4408</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Демидова</surname><given-names>В. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Demidova</surname><given-names>V. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Демидова Валентина Семеновна, д. б. н. заведующая клинико-диагностической лабораторией</p><p>Москва</p></bio><bio xml:lang="en"><p>Demidova Valentina S., Dr Bio Sci, head of Clinical Diagnostic Laboratory</p><p>Moscow</p></bio><email xlink:type="simple">Demidova@ixv.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ «Национальный медицинский исследовательский центр хирургии имени А. В. Вишневского» Минздрава России;&#13;
ФГАОУ ВО «Российский университет дружбы народов имени Патриса Лумумбы»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>A.V. Vishnevsky National Medical Research Center of Surgery;&#13;
Peoples’ Friendship University of Russia named after Patrice Lumumba</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГБУ «Национальный медицинский исследовательский центр хирургии имени А. В. Вишневского» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>A.V. Vishnevsky National Medical Research Center of Surgery</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>23</day><month>01</month><year>2025</year></pub-date><volume>0</volume><issue>35</issue><issue-title>Кардиология. Неотложная медицина (4)</issue-title><fpage>90</fpage><lpage>94</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Струнин О.В., Терехова Р.П., Козлова А.В., Демидова В.С., 2025</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="ru">Струнин О.В., Терехова Р.П., Козлова А.В., Демидова В.С.</copyright-holder><copyright-holder xml:lang="en">Strunin O.V., Terekhova R.P., Kozlova A.V., Demidova V.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.med-alphabet.com/jour/article/view/4138">https://www.med-alphabet.com/jour/article/view/4138</self-uri><abstract><p>Актуальность. Инфекции, связанные с оказанием медицинской помощи (ИСМП), являются существенной проблемой отделений интенсивной терапии и реанимации. Они способствуют росту смертности, увеличивают сроки госпитализации и повышают расходы, связанные с лечением.Цель исследования. Оценка эффективности снижения микробного фона и перекрестной передачи патогенных микроорганизмов, связанных с оказанием медицинской помощи в палатах реанимации хирургического стационара при системном применении импульсной ультрафиолетовой системы «Альфа‑06А» с устройством «Ареал» (ООО «НПП «Мелитта», Россия).Материалы и методы. Система обеззараживания воздуха, поверхностей и локальных зон помещений «Альфа‑06А» с устройством «Ареал» (ООО «НПП «Мелитта», Россия) использовалась в отделении реанимации в течение 2-х месяцев – августа и сентября 2024 г. Устройство «Ареал» направляет ультрафиолетовое излучение, генерируемое импульсной ксеноновой лампой установки «Альфа‑06» в ограниченный сектор, остальная часть помещения конструктивно защищена от попадания прямого УФ-излучения, что позволило проводить обработку в присутствии пациентов и персонала. Применение установки дополняло стандартные противоэпидемические мероприятия. В конце изучаемого периода были ретроспективно оценены результаты микробиологических исследований и проведено сравнение с результатами контрольного периода.Результаты. Отмечено статистически достоверное (критерий Фишера 0,00383, р&lt;0.05) десятикратное снижение количества позитивных проб с поверхностей в период обработки в режиме «Ареал». Снижение бактериальной загрязненности окружающей среды привело к появлению отчетливой тенденции к урежению случаев контаминации пациентов различной флорой, а приобретение полирезистентных микроорганизмов статистически достоверно снизилось на 100 % (p&lt;0.5). Как следствие, применение системы «Альфа» в режиме «Ареал» снизило расходы на дорогостоящие антибактериальные препараты на 18,9 % в абсолютном и 7,4 % в относительном выражении.Заключение. Систематическое применение «Альфа‑06А» совместно с устройством «Ареал» в процессе повседневной работы отделения реанимации значительно снижает обсемененность поверхностей помещений микроорганизмами. Это отражается на снижении числа позитивных посевов из различных локусов пациентов. Также снижается число случаев персистирования полирезистентных проблемных бактерий группы ESKAPE. Улучшение микробиологического фона показывает отчетливый экономический эффект в части расходов на дорогостоящие антибактериальные препараты.</p></abstract><trans-abstract xml:lang="en"><p>Relevance. Healthcare-associated infections (HAIs) are a significant problem in intensive care units. They contribute to increased mortality, lengthen hospital stays and increase treatment-related costs.The aim of the study was to evaluate the effectiveness of reducing the microbial background and cross-transmission of pathogenic microorganisms associated with the provision of medical care in the intensive care units of surgical hospital with the systemic use of the Alpha‑06A pulsed ultraviolet system with the “Areal” device (Scientific and Production Enterprise «Melitta», Russia).Materials and methods. The Alfa‑06A air, surface and local areas disinfection system with the “Areal” device was used in the intensive care unit for 2 months – August and September 2024. The “Areal” device directs ultraviolet radiation, generated by the pulsed xenon lamp of the Alfa‑06 installation, into a limited sector. The rest of the room is structurally protected from direct UV radiation. It is allowed to use it in the presence of patients and staff. The use of the installation complemented the standard anti-epidemic measures. At the end of the study period, the results of microbiological studies were retrospectively evaluated and compared with the results of the control period.Results. A statistically significant (Fisher’s criterion 0.00383, p&lt;0.05) tenfold decrease in the number of positive samples from surfaces during the treatment period in the «Areal» mode was noted. A decrease in bacterial pollution of the environment led to a distinct tendency to reduce cases of contamination of patients with various bacterial flora, and the acquisition by the patients of multidrug-resistant organisms statistically significantly decreased by 100 % (p&lt;0.5). As a result, the use of the Alpha system in the «Areal» mode reduced the cost of expensive antibacterial drugs by 18.9 % in absolute and 7.4 % in relative terms.Conclusion. The systematic use of Alfa‑06A in conjunction with the “Areal” device in the daily work of the intensive care unit significantly reduces the contamination of surfaces with microorganisms. This is reflected in a decrease in the number of positive samples from various patient loci. The number of cases of persistence of polyresistant problematic bacteria of the ESKAPE group is also decreasing. The improvement of the microbiological background shows a clear economic effect in terms of the cost of expensive antibacterial drugs.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>отделение интенсивной терапии</kwd><kwd>дезинфекция</kwd><kwd>внутрибольничная инфекция</kwd><kwd>микроорганизмы с множественной лекарственной устойчивостью</kwd></kwd-group><kwd-group xml:lang="en"><kwd>intensive care unit</kwd><kwd>disinfection</kwd><kwd>nosocomial infection</kwd><kwd>multidrug-resistant organisms</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Sheng W., Wang J. T., Lu D. C., Chie W. C., Chen Y. C., Chang S. C. Comparative impact of hospital-acquired infections on medical costs, length of hospital stay and outcome between community hospitals and medical centres. Journal of Hospital Infection 2005; 59, 205–214. DOI: 10.1016/j.jhin.2004.06.003</mixed-citation><mixed-citation xml:lang="en">Sheng W., Wang J. T., Lu D. C., Chie W. C., Chen Y. C., Chang S. C. Comparative impact of hospital-acquired infections on medical costs, length of hospital stay and outcome between community hospitals and medical centres. Journal of Hospital Infection 2005; 59, 205–214. DOI: 10.1016/j.jhin.2004.06.003</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Wang J., Liu F., Tartari E., Huang J., Harbarth S., Pittet D., Zingg W. The prevalence of healthcare-associated infections in mainland China: a systematic review and meta-analysis. Infection Control and Hospital Epidemiology 2018;39, 701–709. DOI: 10.1017/ice.2018.60</mixed-citation><mixed-citation xml:lang="en">Wang J., Liu F., Tartari E., Huang J., Harbarth S., Pittet D., Zingg W. The prevalence of healthcare-associated infections in mainland China: a systematic review and meta-analysis. Infection Control and Hospital Epidemiology 2018;39, 701–709. DOI: 10.1017/ice.2018.60</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">David J. Weber 1, Anderson D., William A. Rutala The role of the surface environment in healthcare-associated infections. Current Opinion in Infectious Diseases 2013;26, 338–344. DOI: 10.1097/QCO.0b013e3283630f04</mixed-citation><mixed-citation xml:lang="en">David J. Weber 1, Anderson D., William A. Rutala The role of the surface environment in healthcare-associated infections. Current Opinion in Infectious Diseases 2013;26, 338–344. DOI: 10.1097/QCO.0b013e3283630f04</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Harbarth S., Sax H., Gastmeier P. The preventable proportion of nosocomial infections: an overview of published reports. Journal of Hospital Infection 2003;54, 258–266. PMID: 12919755 DOI: 10.1016/s0195–6701 (03) 00150-6</mixed-citation><mixed-citation xml:lang="en">Harbarth S., Sax H., Gastmeier P. The preventable proportion of nosocomial infections: an overview of published reports. Journal of Hospital Infection 2003;54, 258–266. PMID: 12919755 DOI: 10.1016/s0195–6701 (03) 00150-6</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Скопин А. Ю., Мукабенов Ф. А., Матвеева Е. А. Совершенствование системы дезинфектологической профилактики инфекционных болезней с применением нового оборудования для аэрозольной дезинфекции. Дезинфекционное дело. 2020; 3:25–26. DOI: 10.35411/2076–457X-2020-3-22-28</mixed-citation><mixed-citation xml:lang="en">Skopin A. Yu., Mukabenov F. A., Matveeva E. A. Improving the system of disinfectological prevention of infectious diseases using new equipment for aerosol disinfection. Disinfection business. 2020; 3:25–26. (In Russ.). DOI: 10.35411/2076–457X-2020-3-22-28</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Alexandre R. Marra, Marin L. Schweizer, Michael B. Edmond No-touch disinfection methods to decrease multidrug-resistant organism infections: a systematic review and meta-analysis. Infection Control and Hospital Epidemiology 2018;39, 20–31. PMID: 29144223 DOI: 10.1017/ice.2017.226</mixed-citation><mixed-citation xml:lang="en">Alexandre R. Marra, Marin L. Schweizer, Michael B. Edmond No-touch disinfection methods to decrease multidrug-resistant organism infections: a systematic review and meta-analysis. Infection Control and Hospital Epidemiology 2018;39, 20–31. PMID: 29144223 DOI: 10.1017/ice.2017.226</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Шашковский С. Г., Калинчук Т. А., Поликарпов Н. А., Гольдштейн Я. А., Гончаренко И. В. Оборудование для обеззараживания помещений в ЛПУ на основе импульсной ультрафиолетовой технологии, Журнал «Поликлиника» № 3, 2009 г.</mixed-citation><mixed-citation xml:lang="en">Shashkovsky S. G., Kalinchuk T. A., Polikarpov N. A., Goldstein Ya.A., Goncharenko I. V. Equipment for disinfection of premises in healthcare facilities based on pulsed ultraviolet technology, Journal «Polyclinic» No. 3, 2009 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Ушаков И., Новикова Н., Шашковский С. Стерилизующий свет. Наука в России, 2011, № 6(186), с. 11–16.</mixed-citation><mixed-citation xml:lang="en">Ushakov I., Novikova N., Shashkovsky S. Sterilizing light. Science in Russia, 2011, No. 6 (186), pp. 11–16. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Архипов В. П., Камруков А. С., Козлов Н. П., Шашковский С. Г., Яловик М. С. Плазменно-оптические технологии обеззараживания и обезвреживания объектов среды обитания. Вестник МГТУ им. Н. Э. Баумана. Сер. «Машиностроение». 2011. – С. 120–134.</mixed-citation><mixed-citation xml:lang="en">Arkhipov V. P., Kamrukov A. S., Kozlov N. P., Shashkovsky S. G., Yalovik M. S. Plasma-optical technologies for disinfection and neutralization of environmental objects. Bulletin of Bauman Moscow State Technical University. Series «Mechanical Engineering». 2011. – P. 120–134. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Гольдштейн Я. А., Голубцов А. А., Киреев С. Г., Шашковский С. Г. Новое поколение импульсных УФ-установок серии «Альфа» для оперативного обеззараживания воздуха и поверхностей помещений, журнал «Медицинский альманах», № 3 (60), сентябрь 2019 г.</mixed-citation><mixed-citation xml:lang="en">Goldstein Ya.A., Golubtsov A. A., Kireev S. G., Shashkovsky S. G. New generation of pulsed UV installations of the «Alpha» series for prompt disinfection of air and surfaces of premises, journal «Medical Almanac», No. 3 (60), September 2019 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Шестопалов Н. В., Акимкин В. Г., Гольдштейн Я. А., Голубцов А. А., Киреев С. Г., Поликарпов Н. А., Шашковский С. Г. ООО «НПП «Мелита», Исследование бактерицидной эффективности обеззараживания воздуха и открытых поверхностей импульсным ультрафиолетовым излучением сплошного спектра, Научно-практический рецензируемый журнал «Эпидемиология и гигиена» серии «Медицинский алфавит» № 18 (315) 2017 г.</mixed-citation><mixed-citation xml:lang="en">Shestopalov N. V., Akimkin V. G., Goldstein Ya.A., Golubtsov A. A., Kireev S. G., Polikarpov N. A., Shashkovsky S. G. OOO NPP Melita, Study of the bactericidal efficiency of air and open surface disinfection with continuous spectrum pulsed ultraviolet radiation, Scientific and practical peer-reviewed journal Epidemiology and Hygiene, Medical Alphabet series, No. 18 (315), 2017 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Акимкин В.Г Импульсные ультрафиолетовые установки для одновременного обеззараживания воздуха и поверхностей, Журнал «Главная медицинская сестра» № 5, май, 2016 г.</mixed-citation><mixed-citation xml:lang="en">Akimkin V. G. Pulse ultraviolet units for simultaneous disinfection of air and surfaces, Chief Nurse Magazine No. 5, May, 2016 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Dong Z., Zhou N., Liu G., Zhao L. Role of pulsed-xenon ultraviolet light in reducing healthcareassociated infections: a systematic review and meta-analysis. Epidemiology and Infection 2020;148; e165, 1–10. Doi.org/10.1017/S 095026882000148X</mixed-citation><mixed-citation xml:lang="en">Dong Z., Zhou N., Liu G., Zhao L. Role of pulsed-xenon ultraviolet light in reducing healthcareassociated infections: a systematic review and meta-analysis. Epidemiology and Infection 2020;148; e165, 1–10. Doi.org/10.1017/S 095026882000148X</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kitagawa H., Mori M., Kawano R., Hara T., Kashiyama S., Hayashi Y., Sasabe Y., Ukon K., Shimokawa N., Nomura T., Omori K., Shigemoto N., Shime N., Ohge H. Combining pulsed xenon ultraviolet disinfection with terminal manual cleaning helps reduce the acquisition rate of methicillin-resistant Staphylococcus aureus. American Journal of Infection Control; 2021; V.49, Issue 8, August, P. 1048–1051/https://doi.org/10.1016/j.ajic.2021.01.019</mixed-citation><mixed-citation xml:lang="en">Kitagawa H., Mori M., Kawano R., Hara T., Kashiyama S., Hayashi Y., Sasabe Y., Ukon K., Shimokawa N., Nomura T., Omori K., Shigemoto N., Shime N., Ohge H. Combining pulsed xenon ultraviolet disinfection with terminal manual cleaning helps reduce the acquisition rate of methicillin-resistant Staphylococcus aureus. American Journal of Infection Control; 2021; V.49, Issue 8, August, P. 1048–1051/https://doi.org/10.1016/j.ajic.2021.01.019</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Kitagawa H., Mori M., Hara T., Kashiyama S., Shigemoto N., Ohge H. Effectiveness of pulsed xenon ultraviolet disinfection for Clostridioides (Clostridium) difficile surface contamination in a Japanese hospital. American Journal of Infection Control; 2021; Jan;49(1): 55–58. PMID: 32485271 DOI: 10.1016/j.ajic.2020.05.032</mixed-citation><mixed-citation xml:lang="en">Kitagawa H., Mori M., Hara T., Kashiyama S., Shigemoto N., Ohge H. Effectiveness of pulsed xenon ultraviolet disinfection for Clostridioides (Clostridium) difficile surface contamination in a Japanese hospital. American Journal of Infection Control; 2021; Jan;49(1): 55–58. PMID: 32485271 DOI: 10.1016/j.ajic.2020.05.032</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
